MPPT charge mode, conversion efficiency up to 99%;
Maximum PV input is DC 150V;
Support all kind of batteries, non-normal type can be set on PC software;
Three stage charge mode: fast charge, constant charge, floating charge);
With temperature sensor;
Anderson connection port, avoide reverse connection;
RS485communication port, free PC software;
Intelligent design, the device can be upgraded online;
The devices can suffer the temperature not less than 105°C;
Perfect protection: input low voltage, input overvoltage, input polarity reversal, output over voltage, short-circuit over temperature;
Unlimited parallel;
discharge mode;
LCD and LED show all kinds of parameter;
CE,ROHS,FCC certifications approved. The device also can support to pass the other certifications;
2 years warranty and 3~10 years extended warranty service also can be provided.
MPPT charger connection diagram :
		    
			
		    
			Material & Application:
Off grid solar system MPPT charger application:
		    
			solar power generation application
		    
			| 
 Model  | 
 48L-80A  | 
 48L-100A  | 
 48H-80A  | 
 96H-50A  | 
||
| 
 Product Category  | 
 Controller type  | 
 Controller with maximum power point tracking (MPPT)  | 
||||
| 
 MPPT efficiency  | 
 ≥99.5%  | 
|||||
| 
 System voltage  | 
 auto recognition  | 
 48V  | 
 96V  | 
|||
| 
 Heat dissipation method  | 
 Natural cooling  | 
|||||
| 
 Input characteristics  | 
 PV maximum open circuit voltage (VOC)  | 
 DC150V  | 
 DC300V  | 
|||
| 
 Start charging voltage point  | 
 Higher than battery voltage 3V  | 
 Higher than battery voltage 10V  | 
||||
| 
 Input low voltage protection point  | 
 Higher than the current battery voltage 2V  | 
 Higher than the current battery voltage 5V  | 
||||
| 
 Input overvoltage protection point  | 
 DC150V  | 
 DC300V  | 
||||
| 
 Solar panel rated input power  | 
 12V system  | 
 1040W  | 
 1300W  | 
 -  | 
 -  | 
|
| 
 24V system  | 
 2080W  | 
 2600W  | 
 -  | 
 -  | 
||
| 
 36V system  | 
 3120W  | 
 3900W  | 
 -  | 
 -  | 
||
| 
 48V system  | 
 4160W  | 
 5200W  | 
 4160W  | 
 -  | 
||
| 
 96V system  | 
 -  | 
 -  | 
 -  | 
 5200W  | 
||
| 
 Charging characteristics  | 
 Applicable battery type  | 
 Sealed lead acid battery, colloidal lead acid battery, open lead acid battery (can also customize parameters for other types of battery charging)  | 
||||
| 
 Charging current  | 
 80A  | 
 100A  | 
 80A  | 
 50A  | 
||
| 
 charging method  | 
 Three stages: constant current (fast charge), constant voltage, floating charge  | 
|||||
| 
 Load characteristics  | 
 Load voltage  | 
 Same battery voltage  | 
||||
| 
 Rated load current  | 
 80A  | 
 100A  | 
 80A  | 
 50A  | 
||
| 
 Load control mode  | 
 Normally open normally closed mode / dual time control mode / light control mode / light control – fixed time control mode  | 
|||||
| 
 Display/communication  | 
 Display method  | 
 HD LCD segment code backlight display  | 
||||
| 
 communication method  | 
 8-pin RJ45 interface / RS485 / support host computer monitoring / support WIFI module expansion to achieve app cloud monitoring  | 
|||||
| 
 Other attributes  | 
 Protective function  | 
 Input and output over-voltage protection, anti-reverse protection, etc.  | 
||||
| 
 Working temperature  | 
 -20℃~+50℃  | 
|||||
| 
 Storage temperature  | 
 -40℃~+75℃  | 
|||||
| 
 IP protection level  | 
 IP67  | 
|||||
| 
 Maximum wiring size  | 
 50mm2  | 
|||||
| 
 Net weight (kg)  | 
 12.8  | 
|||||
| 
 Gross weight (kg)  | 
 13  | 
|||||
| 
 Product size (mm)  | 
 500*350*140  | 
|||||
| 
 Packing size (mm)  | 
 600*448*265  | 
|||||